Replace Microtest (5238) Transformer Test System with (SS3302) Automatic Transformer Test System

 Detailed Photos Automatic common inductor balance testerProduct DescriptionDescription of SS3250/3252/3302 automatic transformer tester :The SS3250/3252/3302 transformer test instrument is a precision test system, designed for transformer production line or incoming/outgoing inspection in quality control process,

Featured Products

 

Detailed Photos

 Automatic common inductor balance tester
Replace Microtest (5238) Transformer Test System by (SS3302) Automatic Transformer Test SystemReplace Microtest (5238) Transformer Test System by (SS3302) Automatic Transformer Test SystemReplace Microtest (5238) Transformer Test System by (SS3302) Automatic Transformer Test SystemReplace Microtest (5238) Transformer Test System by (SS3302) Automatic Transformer Test SystemReplace Microtest (5238) Transformer Test System by (SS3302) Automatic Transformer Test System
Replace Microtest (5238) Transformer Test System by (SS3302) Automatic Transformer Test System
Replace Microtest (5238) Transformer Test System by (SS3302) Automatic Transformer Test System


Replace Microtest (5238) Transformer Test System by (SS3302) Automatic Transformer Test System
Replace Microtest (5238) Transformer Test System by (SS3302) Automatic Transformer Test System

Product Description


Description of SS3250/3252/3302 automatic transformer tester :
The SS3250/3252/3302 transformer test instrument is a precision test system, designed for transformer production line or incoming/outgoing inspection in quality control process, with high stability and high reliability. With the enhanced capability in turn ratio measurement, they can solve the measuring problems of low coupling coefficient, transformer's turn ratio and turn number with more precise measurement. In addition to transformer scanning test function, the 3302/3252 have LCR Meter function. Operator-friendly and value-added, they can help you reduce production cost greatly.

Feature of SS3250/3252/3302 automatic transformer tester :
1. Test frequency: 20Hz-200KHz/1MHz, 0.02% accuracy.
2. Basic accuracy: 0.1%
3. Output impedance modes, measurement results are compatible with other well-known LCR meters.
4. Enhanced Turn Ratio measurement accuracy for low permeability core
5. Fast Inductance/Turn Ratio measurement speed up to 80 meas. /sec
6. Fast DCR measurement speed up to 50 meas. /sec
7. Bias current source directly control capability (3252/3302)
8. 320x240 DOT-matrix LCD display
9. Support versatile standard and custom-design test jigs
10. Four-terminal test for accurate, stable DCR, inductance and turn ratio measurements
11. Build-in comparator; 10 bin sorting with counter capability (3252/3302)
12. 2M SRAM memory card, for setup back-up between units
13. Standard RS-232, HANDLER, PRINTER interface
14. 50 internal instrument setups for store/recall capability

Order items of SS3250/3252/3302 automatic transformer tester :
A. SS3250/3252/3302
B. 3001A(scaning testing box)
C. Universal fixture
D. Custom-made fixture (optional)
E. Memory card (optional) 

Automatic transformer tester

Model
 
3250
 
3252/3302
 
Main functions
 
transformer Auto. analyzer
 
transformer Auto. analyzer + LCR meter
 
Analyse parameter
 
Transformer Auto. Meas.
 
Turn ratio, Phase, Turn, L, Q, L. K, Balance, ACR, Cp, DCR, Pin short.
 
LCR Meas.
 
General L, C, R, DCR
 
L, C, R, Z, Y, DCR, Q, D, R, X, θ
 
Meas. Signal
 
Meas. Level
 
Turn
 
10mV~10V, ± 10%, 10mV/Step
 
Other
 
10mV~2V, ± 10%, 10mV/Step
 
Meas. Frequency
 
Turn
 
3250, 3252: 1KHZ ~ 200KHZ, ± 0.02%
 
3302: 1KHZ~1MHZ ± 0.02%, Min. display: 0.01HZ
 
other
 
3250, 3252: 20HZ ~ 200KHZ, ± 0.02%
 
3302: 20HZ~1MHZ ± 0.02%, Min. display: 0.01HZ
 
Out impendance
 
Turn
 
10Ω , Meas. level≤ 2V
 
50Ω , Meas. level > 2V
 
Other
 
Constant=OFF: according to resistance value range to be
 
Constant=320X: 100Ω ± 0.5%
 
Constant=107X: 25Ω ± 0.5%
 
Constant=106X: 50Ω   100mA± 0.5%(setup 1V )
 
inductance load < 10Ω , 10Ω ± 10%, impedance≥ 10Ω  
 
Meas. Display range
 
L, L. K
 
0.00001uH ~ 9999.99H
      0.00001pF ~ 999.999mF
C
 
0.00001pF ~ 999.999mF
 
Q, D
 
0.00001 ~ 99999
 
Z, X, R
 
0.00001Ω ~ 99.9999MΩ
 
Y
 
0.01nS ~ 99.9999S
 
θ
 
-90.00 ~ +90.00
 
DCR
 
0.01mΩ ~ 99.9999MΩ
 
Turn
 
0.01 ~ 99999.99T(S windings voltage < 100Vrms)
 
Pin - Short
 
11 windings, pin and pin
 
Base accuracy
 
L, L. K, C, Z, X, Y, R, DCR
 
0.1% (AC parameter 1KHZ )
 
Q, D
 
0.0005 (1KHZ )
 
θ
 
0.03° (1KHZ )
 
Turn
 
0.5% (1KHZ )
 
Meas. speed (fast )
 
L, L. K, C, Z, X, Y, R, Q, D, θ
 
80Meas. /S
 
DCR
 
50Meas. /S
 
Turn
 
10Meas. /S
 
Judgement way
 
Transformer Auto. Meas.
 
the judgement of all parameters of NG or good which be output by ordered processor.
 
LCR Meas.
 
parameters be displayed.
 
10 levels sorting and total No. be output by ordered processor. The judgement of parameter of good or NG be output by standard processor.
 
Displayer revising function
 
320*240 points LCD displayer
 
Open / Short, load revising
 
Memory
 
50 groups setup, can be extended by memory card.
 
Equivalent circuit model
 
series, parallel
 
Trigger
 
inner, manual, external
 
Common Spec.
 
Environment
 
10º C ~ 40º C, 10% ~ 90%RH
 
Power consuming
 
Max. 140W
 
Power
 
90 ~ 125V AC or190~250V AC   48HZ~62HZ
 
Weight
 
  8.5KG
 
Meas. (W× H× L )
 
430× 180× 320mm
 
Our Services

Our Services:

Service tenet
Provide you the best service with "fast + satisfactory + safe".
Warranty period
12 months long after the user received the product.
Warranty items
Only for abnormal breakdown caused by the machine design or manufacture defect,
free repair and accessory will be provided.
Technology service ability
All service engineers with many years experience are gotten special technology training, who can deal with various breakdown problem.
Guide the user to use accurately and how to maintain the product.
Provide free consultation about production process technology of electronic products.
Service after sell
In order to guarantee the machine used normally, we'd have training on how to operate, use and maintain our product by English manual, video, guiding on line.
Use instruction
Apply for the right complete size of product, otherwise, the wrong dimensions will affect the use effect.
Do ensure using the product accord to the use instruction completely.Do not exceed the scope of application of the products.
Maintain the product after use,Damp proof, rust proof, leak proof, explosion-proof, regular maintenance and inspection should    
be taken care. All done help to extend the use period.
User document management
Establish perfect user document management in EPR system, Every product running details would be followed to manage.    The users would be taken good care.
About product
1. Product photo: All product photos are taken by real product, There is the color aberration between the product and photo, which is caused by shoot light, product size, manual technology and computer display etc. It's not quality problem. Parts of products are changed in appearance due to technology revolutionary and process improvement. SanShine would ensure the parameter of product is unchanged, The product couldn't affect to use.
2.Product size: All parameters are all measured by manual just for reference. There is a small deviation due to the difference of measure tools, lot products and produce process. Real size should be accordance with the final delivery product.
3.Quality inspection: All products should be inspected strictly before shipment. Ensure the good function and appearance.
Packaging & Shipping

Packaging & Shipping:

Package and transport
General package(Paper carton or plastic bag):  For small goods, Package it with form and pack paper to guarantee unbroken during the transport.
Wooden case package: For larger scale goods as machine equipment etc, we have special skilled carpenter, who would make the proper wooden case with exact thickness,density,length. The up arrow ↑marked on the outer wooden case. Buffer material would be put in the wooden case to prevent crack and shock. We will inform you the delivery note. You just need to wait for phone call, then pick up the goods at the nearest logistic station .(Please let me know in advance if you want get the goods at home.)
Replace Microtest (5238) Transformer Test System by (SS3302) Automatic Transformer Test System
Our Customers

 


Replace Microtest (5238) Transformer Test System by (SS3302) Automatic Transformer Test System
Cantact Us

 

Replace Microtest (5238) Transformer Test System by (SS3302) Automatic Transformer Test System

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours