11kv S11-M series oil-immersed distribution transformer

11kV S11-M Series Oil Immersed TransformerCompetitive price and good qualityWelcome customized productsBasic information:1. Standards: GB1094-1996; JB/T10088-2004; GB/T6451-2008; EQV IEC600762. Voltage Grade: 6kv, 10kv, 11kV, 13.8kv, 15kv3. Voltage Regulation Mode: Off circuit tap changing

Featured Products

11kV S11-M Series Oil Immersed Transformer
Competitive price and good quality
Welcome customized products

Basic information:
1. Standards: GB1094-1996; JB/T10088-2004; GB/T6451-2008; EQV IEC60076
2. Voltage Grade: 6kv, 10kv, 11kV, 13.8kv, 15kv
3. Voltage Regulation Mode: Off circuit tap changing or on load tap changing
4. Tapping Range: ± 5%, ± 2× 2.5%, ± 4× 2.5% or others
5. Frequency: 50Hz; 60Hz
6. Phase: Three phase
7. Connection Sign: Yyn0, Dyn11, Dyn5 or others
8. Short Circuit Impedance: Standard impedance (For details see technical data sheet)

Main characteristics of oil-immersed transformer:
1. High short-circuit resisting ability and fine mechanical performance
2. Low power consumption, low partial-discharge and low noise
3. No leakage, free of core and winding body lifting and no maintenance

Main technical points of oil-immersed transformer:
1. Scientific computing method:
Adopt advanced computing software for electromagnetic heat and mechanical power to calculate the distribution of electromagnetic field and magnetic leakage, choose insulation tolerance and analyze wave process; The software is used for simulation design of plane and three-dimensiona dynamic model, which guarantees the products a reliable performance and a rational structure.

2. Rational array of structure:
According to the computing result, choose rational insulation structure, wire specification and magnetic flux density.
Adopt magnetic screen for oil tank. Calculate the natural vibration frequency of drawplate and iron core. Adopt multistage step lapped joint fully-oblique structure...
Reduce on-load power consumption and noise. Increase the short circuit resisting ability by adopting round bar and cardboard sleeve.
Reduce the partial-discharge by applying rounding process on the fringes of insulation parts and metal parts and metal parts inside the transformer.
3. Advanced processing methods:
Cut the iron core automatically, so the precision is high and the burr is very small.
Adopt non-overlapping upper yoke processing.
Apply double-H setting glue on the surface, Coil the wire vertically, and a numerical control tension device is needed.
Set-assemble is adopted for the body of transformer. Integral preassemble is adopted for the wire lead.
Full automatic control gas-kerosene drying process is adopted for the body of transformer. Preassemble is adopted for general assembly.

4. Perfect quality assurance system: Control the quality of products according to the ISO19001 quality standards.

5. Systematic data management: ERP&PDM data management programs are adopted during the whole process from sale to leaving factory
Technical Data of 10kV S11-M Series Power Transformer
   Loss (kW)  Weight (kg)(mm)Gauge
Rated CapacityVoltage Group(kV)Connection                 (75)No-load currentImpedance   (L)(W)(H)  
(kVA)HVLVNo-loadLoad%%MachineOilGrossDimensionVerticalHorizontal
200   0.343.151.84.5650160100011807401270660660
250   0.43.61.7770200119012307801340660660
315   0.484.31.6900215136012608101370660660
400   0.575.21.51080260165013809001390660660
500   0.686.21.41250280189014009201450660660
630   0.817.31.3 14703402245158010201430820820
800   0.988.91.217353852645166510701520820820
1000   1.1510.51.119104302980174011601550820820
125011  1.3612.42122105903640182012101740820820
160010.56.3Yd111.6414.850.926406804270184012401860820820
2000106Yyn01.9617.820.95.528907254775221019201970820820
25003.15Dyn112.3120.70.8 3460910571022601970199510701070
31506  2.7324.30.842301350708523202280236010701070
40006.3  3.3628.80.750251675815024602480247510701070
5000   3.99330.760201940961025752640259010701070
6300   4.7636.90.6812525501266026402820281010701070
8000   6.5240.50.55962027801510027102840304010701070
10000   7.747.70.551166030701748028502880326514751475
(Note): (Tapping range of high voltage) ± 5%; ± 2× 2.5%, Frequency: 50Hz.