300kVA Pad Mounted Substation Power Distribution

The product has small volume, convenient installation and maintenance, low noise, low loss, security, overload ability, full protection, etc. Apply new village, green belts, parks, station hotel, airport, construction etc.ZGS series preinstalled type box-type substation (American), applicable to 10 kv ring network power supply,

Featured Products

The product has small volume, convenient installation and maintenance, low noise, low loss, security, overload ability, full protection, etc. Apply new village, green belts, parks, station hotel, airport, construction etc.

ZGS series preinstalled type box-type substation (American), applicable to 10 kv ring network power supply, double power supply or terminal power supply system, as a substation, measuring, control and protection devices.

This product meets the following criteria:

GB/T17467-1998 "high pressure low pressure preinstalled type transformer substation"

DL/T537-93 order 6 to 35 kv box substation technical conditions"

 

 

Conditions of use

Altitude does not exceed 1000 m;

Ambient temperature: - 35 ºC ~ + 40 ºC;

Relative humidity: day average no greater than 95%, the monthly average no greater than 90%;

Mounting ambicnt: no fire and explosion danger, chemical corrosive gas and well ventilated place, the ground tilt Angle is not more than 3 °.

 

   

Function and characteristics of the

All insulation, fully sealed, avoid less maintenance, reliable guarantee personal safety;

Compact structure, volume is only with the capacity of the third - 1/5, low height;

Can be used box-type structure, to avoid contamination of transformer oil tank;

High side with double fuse full range of protection, greatly reduce the cost;

Can use ring network, also can be used in the terminal, cable head in 200 when a load current emergency plug;

Box USES cellular double sandwich composite panels, the function of the insulating and cooling;

Low voltage side mounted electronic phase protector, when there is abnormal voltage in the system, can quickly breaking into the Lord switch;

High side oil-immersed type load switch or SF6 load switch, electric upgrade, lays the foundation for the realization of the distribution network automation.

Adopt oil-immersed integrated or performance better S11 series transformer.
 

TECHNICAL SPECIFICATION FOR TRANSFORMERS
NO.DescriptionUnitGuaranteed Value
1Country of Origin CHINA
2Standard IEC60076-11
4Brand pengbian
5Installation outdoor
6Max. ambient temperature -30ºC~45ºC
7Altitude ≤1500m
8Rated Power kVA300
10Primary Voltage kV2.4
11Secondary VoltagekV0.4
12Rated FrequencyHz60
13Cooling System  ONAN
14IP protection class IP68
15Number of winding 2
16Number of phase 3
17Tap Range ±5%
18Refrigerant oil
 Losss at 100% load  
19No-load lossesw1000
20Load lossesw6200
21Short circuit impedance%4
22Mean temp. rise in the HV/LV windings   65K
23Insulation Class HV/LV Class A
24Basic insulation level(BIL)  
a)PrimarykV40
b)SecondarykV0
24Power frequency withstand voltage  
a)PrimarykV10
b)SecondarykV5
25Vector Group Dyn11
27Core material Grain oriented silicon steel
Transformer Dimensions Including All Fittings And Weight (Only for reference)
1Dimensions transformer part
a)lengthmm2200
b)widthmm1650
c)heightmm1900
2Total weightkg2600
Tests
1Measurement of Winding ResistanceYes/NoYes
2Dielectric testsYes/NoYes
3Voltage Ratio and Vector Group testYes/NoYes
4No-load Losses and No-load Current testYes/NoYes
5Test of Impedance Voltage and Load losses Yes/NoYes
6Induced Voltage Withstand Yes/NoYes
300kVA Pad Mounted Transformer Substation Power Distribution

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours